CONCRETE - Recording Beam Testers
(Flexural Strength of Concrete)

 



Rainhart Series 416

ASTM C78, ASTM Designation: C 293, AASHTO Designation: T177, Test Method Tex-420-A

CAT. NO. 416TL Recording Beam Tester - To test the flexural strength of concrete(using simple 6x6 in. beam with third-point loading, ASTM Designation: C 78, AASHT Designation: T 97, CRD-C16). Complete with 416TH Third-point Loading Head; Operating and Service Manual; plastic Dust Cover; 78C16 Recording Charts, Box/100; and 01085 Recording Charts, Box/100. Approx.Ship.Wt.240 lbs.

CAT.NO. 416CL Recording Beam Tester - To test the flexural strength of concrete (using simple 6x6 in. beam with center-point loading, ASTM Designation: C 293, AASHTO Designation: T 177, Test Method Tex-420-A). Complete with 416CH Center-point Loading Head; Operating and Service Manual; plastic Dust Cover; 416CC Recording Charts, Box/100; and 01077 Recording Charts, Box/100. Approx.Sip.Wt. 237 lbs.

  


CAT. NO. 416CL
Recording Beam Tester

CAT. NO. 400 Elastic Calibration Device–To test the flexural strength of concrete (using simple 6X6” beam with center-point loading, ASTM Designation: C 293, AASHTO Designation: T177, Test Method Tex-420-A). Complete with 416CH Center-point Loading Head; Operating and Service Manual; plastic Dust Cover: 416CC Recording Charts, Box/100; and 01077 Recording Charts, Box/100. Approx. Ship. Wt. 237 lb.

CAT.NO. 405 Elastic Checking Device - Same as 400 Elastic Calibration Device except 830R20 Ring Dyanometer is factory calibrated. Approx. Ship. Wt. - 45lbs.

CAT.NO. 405R Rental Elastic Checking Device - Identical to 405 Elastic Checking Device. It is factory recalibrated before each shipment. Approx. Ship. Wt. - 45 lbs. Rentals are computed from date of shipment to date received back at Rainhart Co.

  

CAT. NO. 78C16 Recording Charts PKG/400 - To be used with third-point loadings in 416TL Recording Beam Tester or 415UL Beam Breaker. If beam cross-section is 6X6" +/-0.25", a graph accompanying the charts shows which A-B-C spiral to trace for a rate of loading between 140 and 150 psi./min. The H spiral duplicates the rate of loading of older 01085 Recording Charts. Each division of these spirals is 5 psi (estimate to nearest 2 psi.) for an exact 6X6" beam. The graph accompanying the charts also shows the correction percentage to apply to the indicated psi. For any beam 6X6" thru +/- 0.25". Approx. Ship. Wt. 4 lb.

CAT.NO. 416CC Recording Charts, PKG/400 - To be used with center-point loadings in 416CL Recording Beam Tester or 415CL Beam Breaker. Rate of Loading does not exceed 150 psi./min/ for a beam cross-section as small as
5 7/8x 5 7/8 in. Each division of the spiral is 5 psi. (estimate to nearest 2 psi.) for an exact 6x6 " beam. A graph accompanying the charts shows the correction percentage to apply to the indicated psi. for any beam 6x6" thru +/-0.3". Approx. Ship. Wt. 4 lb.

CAT.NO. 01077 Recording Charts, PKG/400 - To be used with center-point loadings in 416CL Recording Beam Tester or 415CL Beam Breaker. Rate of loading is accelerated to 3,000 lb. total load/min. (375 psi./min. for exact 6x6" beam cross-section). Each chart division is 200 lb. (estimate to the nearest 50 lb.) total load. A table accompanying the charts gives the factor to apply to the indicated lb. total load to get the psi. for any beam 6x6" thru +/_5/16". Approx Ship. Wt. 4 lb.


CAT.NO. 01085 Recording Charts, PKG/400 - To be used with third-point loadings in 416TL Recording Beam Tester or 415UL Beam Breaker. Rate of loading does not exceed 150 psi./min. for a beam cross-section as small as 5.65 x 5.65". Each chart division is 200 lb. (estimate to the neares 150 lb.) total load. A table accompanying the charts gives the factor to apply to the indicated lb. total load to get the psi. for any beam 6x6" thru +/_5/16". Approx Ship. Wt. 4 lb.

   